目的:觀察七氟醚靶控用于低流量吸入麻醉維持的臨床規(guī)律及血流動力學變化,尋求靶控下的藥物量化指標。方法:選擇60例20~60歲手術患者,隨機分2組每組30例:P組(丙泊酚)常規(guī)實施全憑靜脈TCI靶控麻醉;S組(七氟醚),實施低流量七氟醚靶控吸入麻醉(BIS值40)。分別記錄誘導前(T1),插管后5(T2)、15(T3)、30(T4)45(T5)、60(T6)、90(T7)、120(T8)min時的、MBP、HR、;Sev組患者加記各個時點的七氟醚IT、ET的MAC值。結果:T2點兩組均比T1 降低(P lt;0.05),S 組高于P組(P lt;0.05),兩組比較T3至T7無顯著性差異(P gt;0.05);S 組T3 至T7 各點ET值無統(tǒng)計學差異,ET%:2.46,約1.4 MAC。結論:(1)七氟醚誘導較靜脈麻醉誘導患者血流動力學穩(wěn)定,(2)低流量七氟醚靶控吸入麻醉維持平穩(wěn),調控簡便,效果良好。
引用本文: 蘇濤,王在義,伍湘伊,徐桂萍. 低流量七氟醚靶控吸入與丙泊酚TCI的臨床對比研究. 華西醫(yī)學, 2009, 24(7): 1695-1698. doi: 復制
1. | 莊心良,曾因明,陳伯鑾.現(xiàn)代麻醉學[M].3版.北京:人民衛(wèi)生出版社,2003:446-448. |
2. | VIITANEN H, ANNILA P, VIITANEN M, et al. Premeditation with midazolam delays recovery after ambulatory sevoflurane anesthesia in children[J].Anesth Analg,1999,8(91):75. |
3. | MALAN TPJ, DINARDO J A, ISNER R J, et al. Cardiovascular effects of servo fluraneeom Pared with those of isofiurane in volunteers[J]. Anesthesiology,1995,83:918-28. |
4. | MAPLESON W W. Effec to fageon MAC analysis[J].Br J Anaesth,1996,76:179-85. |
5. | EGER EL ZND, SAIDNLAN L J, BRANDSTATER B. Minimum alveolar anesthetic concentration:a standard of anesthetic potency[J].Anesthesiology,1965,26:756-63. |
6. | KEIJZER C, PEREZ R S, DE LANGE J J. Compound A and carbon monoxide production from sevoflurane and seven different types of carbon dioxide absorbent in a patient model[J]. Acta Anaesthesiol Scand, 2007, 51:31-37. |
- 1. 莊心良,曾因明,陳伯鑾.現(xiàn)代麻醉學[M].3版.北京:人民衛(wèi)生出版社,2003:446-448.
- 2. VIITANEN H, ANNILA P, VIITANEN M, et al. Premeditation with midazolam delays recovery after ambulatory sevoflurane anesthesia in children[J].Anesth Analg,1999,8(91):75.
- 3. MALAN TPJ, DINARDO J A, ISNER R J, et al. Cardiovascular effects of servo fluraneeom Pared with those of isofiurane in volunteers[J]. Anesthesiology,1995,83:918-28.
- 4. MAPLESON W W. Effec to fageon MAC analysis[J].Br J Anaesth,1996,76:179-85.
- 5. EGER EL ZND, SAIDNLAN L J, BRANDSTATER B. Minimum alveolar anesthetic concentration:a standard of anesthetic potency[J].Anesthesiology,1965,26:756-63.
- 6. KEIJZER C, PEREZ R S, DE LANGE J J. Compound A and carbon monoxide production from sevoflurane and seven different types of carbon dioxide absorbent in a patient model[J]. Acta Anaesthesiol Scand, 2007, 51:31-37.